X-ML17300NCPR-UVAUVC-12+12
Linear LED Modules
  • Default driving method is constant current input.
  • UV-A Wawelenght Range from 380nm up to 410nm
  • UV-C Wawelenght Range from 265nm up to 280nm
  • Channel UVA is standard and can be connected as 1 Parallel 12series.
  • Channel UVC is standard and can be connected as 2 Series 6 Parallels
  • Module Radiant Flux range from 5160 mW to 6120 mW ( For UV-A)
  • Module Radiant Flux range from 102 mW to 126 mW ( For UV-C)
  • Simple installation (e.g. screw)
Documents
  • NC NCSU275T(UV-A) DOWNLOAD
    LED NC NCSU275T(UV-A)
    Wawelenght (nm) 380-390nm
    Module Operating Voltage (V) 43 45 47
    Module Operating Current (mA) 200 250 350
    Branch Operating Current (mA) 200 250 350
    Module Power (W) 8,64 11,25 16,38
    Module Radiant Flux (nW) 5.160 5.760 6.120
    Radiant Flux (m/W) 430 480 510
    PRL PB2D-1CLA-TC(UV-C) DOWNLOAD
    LED PRL PB2D-1CLA-TC(UV-C)
    Wawelenght (nm) 270-275nm
    Module Operating Voltage (V) 12 12,50 13
    Module Operating Current (mA) 350 500 700
    Branch Operating Current (mA) 58 83 117
    Module Power (W) 4,20 6,25 9,10
    Module Radiant Flux (nW) 102 114 126
    Radiant Flux (m/W) 8,5 9,5 10,5
  • PCB Information DOWNLOAD
    Module Code X-ML17300NCPR-UVAUVC-12+12
        Electrical Connection
    PCB Material ALU   UV-A UV-C
    Operating Temperature(°C) -25 ~ +100°C Parallel 1 6
    Storage Temperaature(°C) -25 ~ +85°C Series 12 2
    Thermal Conductivity(W/m-k) 1,5 LED Quantity 12 12
  • X-ML17300NCPR-UVAUVC-12+12 DOWNLOAD
    X-ML17300NCPR-UVAUVC-12+12 DOWNLOAD
  • Applications DOWNLOAD